Dental Instrument disinfection

Aglusept™ DB 400 (5ltr Canister)

Drill bath
Aldehyde-free drill bath with corrosion protection

  • Rapid action (5minutes)
  • Corrosion protection, high material compatibility (good for gum drill too)
  • Broad spectrum of activity and very good cleaning efficiency
  • Biodegradable
  • Approval as a medical device (CE 0124)
Additional DescriptionMore Details

General references

Hygiene prevents infections amongst patients and employees. In order to guarantee high medical standards, careful and thorough hygiene in practices, hospital, etc. is indispensable.

Application of cleaning agents and disinfectants are legally stipulated according to a determined time scheme. The goal is to elimination of infection-relevant germs with standardized,
quantifiable proof of effect for prevention of nosocomial infections.
Active hygienic measures are disinfection, sterilization and the employment of disposal or non- returnable products. Insofar as sterilisation is possible, the sequence “disinfect-clean-sterilise” is to be observed with instrument to be reused again. Vat, spray and wipe methods are utilized for the disinfection of instruments. But vat disinfection is generally preferred.

Field of application:

The drill bath is suitable for cleaning and disinfection of dental drills and any kind of rotating instrument.

Type of preparation:

This is a highly effective and cleaning-active, ready-to-use combination for the dentistry filed with extensive spectrum of activity against bacteria, fungi (Candida albicans) and enveloped viruses. The preparation contains effective corrosion protection and biodegradable.
It can be disposed of diluted with normal wastewater.

Application references:

The drill bath is a ready-to-use solution which is applied undiluted.
Place drill in the solution immediately after use. All >b>surfaces to be disinfected must be completely covered by the solution. There should be no cavities or bubbles. Replace regularly, depending on the degree of soiling.
It is recommended to change the ready-to-use solution daily. Allow to take effect for at least 5 minutes. After completion of the exposure time, thoroughly rinse the drill with water and dry. The water should have at least drinking-water quality.

Composition:

Bis (3-aminopropyl) dodecylamemthylpolyoxyethylammoniumpropionate,

Exposure times:

Bactericidal effect:

VAH / DGHM (Staphylococcos aureus, Enterococcos hirae, Echerichia coli, Pseudomonas aeruginosa, Proteus mirabilis), EN 13727, EN 14561

5 minutes   dirty conditions

Virucidal effect:

Inactivation of enveloped viruses (“limited Virucidal”, e.g. HBV, HCV, HIV), in accordance to BGA (RKI)/ DVV (Vaccinia, BVDV) in accordance to EN 14476:

5 minutes   dirty conditions

Fungicidal / levurocidal effect:

Candida albicans according to VAH / DGHM and EN 13624, EN 14562

5 minutes   dirty conditions

Tuberculocidal effect:

Inactivation of tuberculosis pathogens (surrogate: M. terrae) VAH/DGHM:

5 minutes   dirty conditions

testet according to EN 14476 (BVDV, Vaccinia) and BGA (RKI) DVV

Container delivery forms:

  • Canisters
  • Bulk containers

Chemical-physical data:

Optic:   clear solution

Density:   1.002g/ml

Ph value:   11

Safety informations:

R 36 / 38 Irritating to eyes and skin. S 25 Avoid contact with eyes. S 26 In case of contact with eyes rinse immediately with plenty of water and seek medical advice. S 37/ 39 Wear suitable gloves and eye / face protection.

Expertise:

Our products are scientifically examined and tested according to the latest methods. We will gladly send you copies of our expertise upon request.


ZAR 478.80Price:
Loading Updating cart...

Aglusept™ SS 400 (1000ml Bottle)

Suction system disinfectant concentrate.
Aldehyde- free suction system disinfectant
Tested as instrument disinfection according to the latest guidelines and expertises
For suction systems, amalgam separators and mouth rinse basins of any kind
Tried and tested for many years, e.g. in Ka Vo and Sirona units

No disturbing foam formation
Efficient in utilisation, materially and environmentally compatible
Considerable spectrum of activity within 15 minutes
Listed as suction system disinfection by the VAH
Approved as a medical device ( C€ 0124)

Additional DescriptionMore Details

General references

Hygiene prevents infections amongst patients and employees. In order to guarantee high

Medical standard, careful and thorough hygiene in practices, hospital, hospital, etc is

Indispensable. Application of cleaning agents and disinfectants are legally stipulated

According to a determined time scheme.

Through the daily suction of organic and inorganic substances there is a danger that these

Substances settle in the tubes, begin to dry or present a risk of infection for staff during filter

change. The goal is the elimination of infection- relevant germs with standardized,

quantifiable proof of effect for prevention of nosocomial infections.

Disinfectants can only be effective if the required exposure times and concentrations are

complied with. Non-compliance with exposure times and concentrations, e.g. underdosage,

can lead to insufficient disinfection efficiency. Overdosages are inefficient and

Unnecessarily burden the environment.

Field of application:

Combination preparation for disinfection and cleaning of dental suction system, amalgam

separators as well as mouth rinse basins.

Type of preparation:

Cleaning disinfectant concentrate on basis of quaternary ammonium salts. Aldehyde- free, with pleasant smell, extremely low-foam and material- sparing: fast effectiveness, even in very slight concentrations. Approved as a medical product.

Application references:

To avoid functional disturbances in the suction system and at the same time to ensure hygienic safety, the disinfection should be carried out as follows.

The suction system disinfectant is a disinfectant concentrate which has to be diluted with water before its application. The suction system disinfectant is used in a 2 or 3 % concentration (20/30 ml of concentrate to 1 Liter of water). For this purpose, turn the dosing chamber cap of our practical dosing bottle by a half turn, pump the desired quantity into the dosing chamber by pressing the bottle and mix this quantity with water. Suck ca. one litre of the ready-to-use solution through the suction tubes and allow at least 15 minutes to take effect, e.g. over the lunch break or over night. Depending on the loud, it is recommended to disinfect the suction system one to two times per day, before the lunch break and after the end of treatment.

After the end of the exposure time, flush with water in order to rinse out dissolved contaminants from the tubes.

In the case of a high degree of blood and secretory contaminants, water should be flushed through directly after the treatment. In the event of strong contaminants or longer downtimes, an additional cleaner (e.g. suction system intensive cleaner) should be utilized.

Composition:

Dimethyl dioctyl ammonium chloride, benzyl dimethyl ammonium chloride, surfactants, solubiliser, adjuvants, odorous substance, water.

Exposure times:

Bactericidal effect:

According to VAH/DGHM (Staphylococcos aureus, Enterococcos hirae, Echerichia coli, Pseudomonas aeruginosa, Proteus mirabilis) and EN 1276, EN 13727, EN 14561:

3, 0 % 5 min (dirty conditions) (VAH/DGHM)



3, 0 % 2 min (dirty conditions) (EN 13727, EN 14561)

2, 0 % 15 min (dirty conditions) (VAH/DGHM)

2, 0 % 5 min (dirty conditions) (EN 1276)

Virucidal effect:

Inactivation of enveloped viruses (“limited Virucidal”, e.g. HBV, HCV, HIV)

Fungicidal / effect:

Candida albicans according to VAH/ DGHM and EN 1650, EN 13624,



EN 14562:

3, 0 % 5 min (dirty conditions) (VAH/DGHM)



3, 0 % 2 min (dirty conditions) (EN 13624, EN 14562)

2, 0 % 15 min (dirty conditions) (VAH/DGHM)

2, 0 % 5 min (dirty conditions) (EN 1650)

Dilution table for the concentrate:

SOLUTION 2%
1 litre 20 ml
2 litre 40 ml
3 litre 60 ml
5 litre 100 ml
10 litre 200 ml

Recommendation of supporting / supplementary product:

  • Suction system intensive cleaner
  • Mouth rinse basin disinfection
  • Suction cup
  • Accessories (canister pumps, canister tap, canister key, etc.)

Container delivery forms:

High- quality packaging solutions according to customer request, e.g. in

  • Practical dosing bottle with dosing container
  • Canister
  • Bulk containers

Chemical- physical data:

Optics: nearly clear solution

Density: ca 1.0 g/ cm at 20 C

Ph value: 8-9

Safety references:

 

R 36 / 38 Irritating to eyes and skin.

S 24 / 25 Avoid contact with the skin and eyes. S 26 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. S 28 After contact with skin, wash immediately with plenty of water S 37/ 39 wear suitable gloves and eye / face protection.



Expertise:

Our product are scientifically examined and tested according to the latest methods. We will Gladly send you copies of our expertise upon request.


ZAR 267.22Price:
Loading Updating cart...

Aglusept™ DB 400 (2000ml Bottle)

Drill bath
Aldehyde-free drill bath with corrosion protection

  • Rapid action (5minutes)
  • Corrosion protection, high material compatibility (good for gum drill too)
  • Broad spectrum of activity and very good cleaning efficiency
  • Biodegradable
  • Approval as a medical device (CE 0124)
Additional DescriptionMore Details

General references

Hygiene prevents infections amongst patients and employees. In order to guarantee high medical standards, careful and thorough hygiene in practices, hospital, etc. is indispensable.

Application of cleaning agents and disinfectants are legally stipulated according to a determined time scheme. The goal is to elimination of infection-relevant germs with standardized,
quantifiable proof of effect for prevention of nosocomial infections.
Active hygienic measures are disinfection, sterilization and the employment of disposal or non- returnable products. Insofar as sterilisation is possible, the sequence “disinfect-clean-sterilise” is to be observed with instrument to be reused again. Vat, spray and wipe methods are utilized for the disinfection of instruments. But vat disinfection is generally preferred.

Field of application:

The drill bath is suitable for cleaning and disinfection of dental drills and any kind of rotating instrument.

Type of preparation:

This is a highly effective and cleaning-active, ready-to-use combination for the dentistry filed with extensive spectrum of activity against bacteria, fungi (Candida albicans) and enveloped viruses. The preparation contains effective corrosion protection and biodegradable.
It can be disposed of diluted with normal wastewater.

Application references:

The drill bath is a ready-to-use solution which is applied undiluted.
Place drill in the solution immediately after use. All >b>surfaces to be disinfected must be completely covered by the solution. There should be no cavities or bubbles. Replace regularly, depending on the degree of soiling.
It is recommended to change the ready-to-use solution daily. Allow to take effect for at least 5 minutes. After completion of the exposure time, thoroughly rinse the drill with water and dry. The water should have at least drinking-water quality.

Composition:

Bis (3-aminopropyl) dodecylamemthylpolyoxyethylammoniumpropionate,

Exposure times:

Bactericidal effect:

VAH / DGHM (Staphylococcos aureus, Enterococcos hirae, Echerichia coli, Pseudomonas aeruginosa, Proteus mirabilis), EN 13727, EN 14561

5 minutes   dirty conditions

Virucidal effect:

Inactivation of enveloped viruses (“limited Virucidal”, e.g. HBV, HCV, HIV), in accordance to BGA (RKI)/ DVV (Vaccinia, BVDV) in accordance to EN 14476:

5 minutes   dirty conditions

Fungicidal / levurocidal effect:

Candida albicans according to VAH / DGHM and EN 13624, EN 14562

5 minutes   dirty conditions

Tuberculocidal effect:

Inactivation of tuberculosis pathogens (surrogate: M. terrae) VAH/DGHM:

5 minutes   dirty conditions

testet according to EN 14476 (BVDV, Vaccinia) and BGA (RKI) DVV

Container delivery forms:

  • Canisters
  • Bulk containers

Chemical-physical data:

Optic:   clear solution

Density:   1.002g/ml

Ph value:   11

Safety informations:

R 36 / 38 Irritating to eyes and skin. S 25 Avoid contact with eyes. S 26 In case of contact with eyes rinse immediately with plenty of water and seek medical advice. S 37/ 39 Wear suitable gloves and eye / face protection.

Expertise:

Our products are scientifically examined and tested according to the latest methods. We will gladly send you copies of our expertise upon request.


ZAR 275.31Price:
Loading Updating cart...

Aglusept™ SS 400 (5ltr Canister)

Suction system disinfectant concentrate.
Aldehyde- free suction system disinfectant
Tested as instrument disinfection according to the latest guidelines and expertises
For suction systems, amalgam separators and mouth rinse basins of any kind
Tried and tested for many years, e.g. in Ka Vo and Sirona units

No disturbing foam formation
Efficient in utilisation, materially and environmentally compatible
Considerable spectrum of activity within 15 minutes
Listed as suction system disinfection by the VAH
Approved as a medical device ( C€ 0124)

Additional DescriptionMore Details

General references

Hygiene prevents infections amongst patients and employees. In order to guarantee high

Medical standard, careful and thorough hygiene in practices, hospital, hospital, etc is

Indispensable. Application of cleaning agents and disinfectants are legally stipulated

According to a determined time scheme.

Through the daily suction of organic and inorganic substances there is a danger that these

Substances settle in the tubes, begin to dry or present a risk of infection for staff during filter

change. The goal is the elimination of infection- relevant germs with standardized,

quantifiable proof of effect for prevention of nosocomial infections.

Disinfectants can only be effective if the required exposure times and concentrations are

complied with. Non-compliance with exposure times and concentrations, e.g. underdosage,

can lead to insufficient disinfection efficiency. Overdosages are inefficient and

Unnecessarily burden the environment.

Field of application:

Combination preparation for disinfection and cleaning of dental suction system, amalgam

separators as well as mouth rinse basins.

Type of preparation:

Cleaning disinfectant concentrate on basis of quaternary ammonium salts. Aldehyde- free, with pleasant smell, extremely low-foam and material- sparing: fast effectiveness, even in very slight concentrations. Approved as a medical product.

Application references:

To avoid functional disturbances in the suction system and at the same time to ensure hygienic safety, the disinfection should be carried out as follows.

The suction system disinfectant is a disinfectant concentrate which has to be diluted with water before its application. The suction system disinfectant is used in a 2 or 3 % concentration (20/30 ml of concentrate to 1 Liter of water). For this purpose, turn the dosing chamber cap of our practical dosing bottle by a half turn, pump the desired quantity into the dosing chamber by pressing the bottle and mix this quantity with water. Suck ca. one litre of the ready-to-use solution through the suction tubes and allow at least 15 minutes to take effect, e.g. over the lunch break or over night. Depending on the loud, it is recommended to disinfect the suction system one to two times per day, before the lunch break and after the end of treatment.

After the end of the exposure time, flush with water in order to rinse out dissolved contaminants from the tubes.

In the case of a high degree of blood and secretory contaminants, water should be flushed through directly after the treatment. In the event of strong contaminants or longer downtimes, an additional cleaner (e.g. suction system intensive cleaner) should be utilized.

Composition:

Dimethyl dioctyl ammonium chloride, benzyl dimethyl ammonium chloride, surfactants, solubiliser, adjuvants, odorous substance, water.

Exposure times:

Bactericidal effect:

According to VAH/DGHM (Staphylococcos aureus, Enterococcos hirae, Echerichia coli, Pseudomonas aeruginosa, Proteus mirabilis) and EN 1276, EN 13727, EN 14561:

3, 0 % 5 min (dirty conditions) (VAH/DGHM)



3, 0 % 2 min (dirty conditions) (EN 13727, EN 14561)

2, 0 % 15 min (dirty conditions) (VAH/DGHM)

2, 0 % 5 min (dirty conditions) (EN 1276)

Virucidal effect:

Inactivation of enveloped viruses (“limited Virucidal”, e.g. HBV, HCV, HIV)

Fungicidal / effect:

Candida albicans according to VAH/ DGHM and EN 1650, EN 13624,



EN 14562:

3, 0 % 5 min (dirty conditions) (VAH/DGHM)



3, 0 % 2 min (dirty conditions) (EN 13624, EN 14562)

2, 0 % 15 min (dirty conditions) (VAH/DGHM)

2, 0 % 5 min (dirty conditions) (EN 1650)

Dilution table for the concentrate:

SOLUTION 2%
1 litre 20 ml
2 litre 40 ml
3 litre 60 ml
5 litre 100 ml
10 litre 200 ml

Recommendation of supporting / supplementary product:

  • Suction system intensive cleaner
  • Mouth rinse basin disinfection
  • Suction cup
  • Accessories (canister pumps, canister tap, canister key, etc.)

Container delivery forms:

High- quality packaging solutions according to customer request, e.g. in

  • Practical dosing bottle with dosing container
  • Canister
  • Bulk containers

Chemical- physical data:

Optics: nearly clear solution

Density: ca 1.0 g/ cm at 20 C

Ph value: 8-9

Safety references:

 

R 36 / 38 Irritating to eyes and skin.

S 24 / 25 Avoid contact with the skin and eyes. S 26 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. S 28 After contact with skin, wash immediately with plenty of water S 37/ 39 wear suitable gloves and eye / face protection.



Expertise:

Our product are scientifically examined and tested according to the latest methods. We will Gladly send you copies of our expertise upon request.


ZAR 940.48Price:
Loading Updating cart...

Aglusept™ SS 400 (2.5ltr Bottle)

Suction system disinfectant concentrate.
Aldehyde- free suction system disinfectant
Tested as instrument disinfection according to the latest guidelines and expertises
For suction systems, amalgam separators and mouth rinse basins of any kind
Tried and tested for many years, e.g. in Ka Vo and Sirona units

No disturbing foam formation
Efficient in utilisation, materially and environmentally compatible
Considerable spectrum of activity within 15 minutes
Listed as suction system disinfection by the VAH
Approved as a medical device ( C€ 0124)

Additional DescriptionMore Details

General references

Hygiene prevents infections amongst patients and employees. In order to guarantee high

Medical standard, careful and thorough hygiene in practices, hospital, hospital, etc is

Indispensable. Application of cleaning agents and disinfectants are legally stipulated

According to a determined time scheme.

Through the daily suction of organic and inorganic substances there is a danger that these

Substances settle in the tubes, begin to dry or present a risk of infection for staff during filter

change. The goal is the elimination of infection- relevant germs with standardized,

quantifiable proof of effect for prevention of nosocomial infections.

Disinfectants can only be effective if the required exposure times and concentrations are

complied with. Non-compliance with exposure times and concentrations, e.g. underdosage,

can lead to insufficient disinfection efficiency. Overdosages are inefficient and

Unnecessarily burden the environment.

Field of application:

Combination preparation for disinfection and cleaning of dental suction system, amalgam

separators as well as mouth rinse basins.

Type of preparation:

Cleaning disinfectant concentrate on basis of quaternary ammonium salts. Aldehyde- free, with pleasant smell, extremely low-foam and material- sparing: fast effectiveness, even in very slight concentrations. Approved as a medical product.

Application references:

To avoid functional disturbances in the suction system and at the same time to ensure hygienic safety, the disinfection should be carried out as follows.

The suction system disinfectant is a disinfectant concentrate which has to be diluted with water before its application. The suction system disinfectant is used in a 2 or 3 % concentration (20/30 ml of concentrate to 1 Liter of water). For this purpose, turn the dosing chamber cap of our practical dosing bottle by a half turn, pump the desired quantity into the dosing chamber by pressing the bottle and mix this quantity with water. Suck ca. one litre of the ready-to-use solution through the suction tubes and allow at least 15 minutes to take effect, e.g. over the lunch break or over night. Depending on the loud, it is recommended to disinfect the suction system one to two times per day, before the lunch break and after the end of treatment.

After the end of the exposure time, flush with water in order to rinse out dissolved contaminants from the tubes.

In the case of a high degree of blood and secretory contaminants, water should be flushed through directly after the treatment. In the event of strong contaminants or longer downtimes, an additional cleaner (e.g. suction system intensive cleaner) should be utilized.

Composition:

Dimethyl dioctyl ammonium chloride, benzyl dimethyl ammonium chloride, surfactants, solubiliser, adjuvants, odorous substance, water.

Exposure times:

Bactericidal effect:

According to VAH/DGHM (Staphylococcos aureus, Enterococcos hirae, Echerichia coli, Pseudomonas aeruginosa, Proteus mirabilis) and EN 1276, EN 13727, EN 14561:

3, 0 % 5 min (dirty conditions) (VAH/DGHM)



3, 0 % 2 min (dirty conditions) (EN 13727, EN 14561)

2, 0 % 15 min (dirty conditions) (VAH/DGHM)

2, 0 % 5 min (dirty conditions) (EN 1276)

Virucidal effect:

Inactivation of enveloped viruses (“limited Virucidal”, e.g. HBV, HCV, HIV)

Fungicidal / effect:

Candida albicans according to VAH/ DGHM and EN 1650, EN 13624,



EN 14562:

3, 0 % 5 min (dirty conditions) (VAH/DGHM)



3, 0 % 2 min (dirty conditions) (EN 13624, EN 14562)

2, 0 % 15 min (dirty conditions) (VAH/DGHM)

2, 0 % 5 min (dirty conditions) (EN 1650)

Dilution table for the concentrate:

SOLUTION 2%
1 litre 20 ml
2 litre 40 ml
3 litre 60 ml
5 litre 100 ml
10 litre 200 ml

Recommendation of supporting / supplementary product:

  • Suction system intensive cleaner
  • Mouth rinse basin disinfection
  • Suction cup
  • Accessories (canister pumps, canister tap, canister key, etc.)

Container delivery forms:

High- quality packaging solutions according to customer request, e.g. in

  • Practical dosing bottle with dosing container
  • Canister
  • Bulk containers

Chemical- physical data:

Optics: nearly clear solution

Density: ca 1.0 g/ cm at 20 C

Ph value: 8-9

Safety references:

 

R 36 / 38 Irritating to eyes and skin.

S 24 / 25 Avoid contact with the skin and eyes. S 26 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. S 28 After contact with skin, wash immediately with plenty of water S 37/ 39 wear suitable gloves and eye / face protection.



Expertise:

Our product are scientifically examined and tested according to the latest methods. We will Gladly send you copies of our expertise upon request.


ZAR 523.37Price:
Loading Updating cart...
Pages: « First « Previous 1 2 Next » Last »